可信组件

Copyright Liaoning Create Cable Co.,Ltd.  All rights reserved  辽ICP备10201789号   Powered by 300.cn ShenYang

Name

600/1000V, PVC Insulated Cables according to IEC 60502-1 (armored)

Affiliate classification
Quantity
-
+
没有此类产品
Detail
Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
 
Construction:
Conductors:
Copper or Aluminum conductor, round stranded or Shaped, Class 2 to IEC 60228, BS EN 60228. also be supplied upon request.
Insulation:
PVC Insulation material and temperature is 70℃ or 90℃ 
Assembly 
Two, Three or Four insulated conductors are laid-up together with non-hygroscopic
Inner Sheath
fillers and the assembly is bedded with an extruded layer of PVC. In case of non armored cables, this layer may be omitted
Armor
Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC 60502 or as per BS 5467, BS 6346. Single
core cables shall be Aluminum wire armor. Aluminum/Steel Tapes applied helically over the bedding of multi-core cables 
as per IEC 60502.
Outer Sheath
Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467. Special type of PVC 
sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant 
PVC are available on
Special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 
60332-3-22, IEC 60332-3-23 and IEC 60332-3-24,can also supply cables with Low Smoke Halogen Free (LSHF) material 
according toIEC 60502-1, BS 7211, BS 6724 or other equivalent standards.
 
Cable Parameters:
PVC insulation
 
Single core( aluminum wire armored)

Nominal Area

mm²

Reference conductor Diameter

mm

Nominal Insulation thickness

mm

Nominal Alum Wire dia.

mm

Nominal Sheath thickness

mm

Reference Overall Diameter

mm

Reference Weight

Kg/Km

1x10

4

1

0.8

1.8

14

300

1x16

5

1

0.8

1.8

15

375

1x25

6.3

1.2

0.8

1.8

16

500

1x35

7.4

1.2

0.8

1.8

18

625

1x50

8.8

1.4

1.25

1.8

20

835

1x70

10.6

1.4

1.25

1.8

22

1075

1x95

12.4

1.6

1.25

1.8

24

1385

1x120

14

1.6

1.6

1.8

26

1700

1x150

15.5

1.8

1.6

1.8

28

2025

1x185

17.4

2

1.6

1.8

31

2450

1x240

20.3

2.2

1.6

1.9

34

3100

1x300

22.7

2.4

2

2

38

3900

1x400

25.4

2.6

2

2.1

42

4875

1x500

28.8

2.8

2

2.2

45

6050

1x630

30.4

2.8

2

2.4

50

7625


Two cores(Galvanized steel wire armored)

Nominal Area

mm²

Reference conductor Diameter

mm

Nominal Insulation thickness

mm

Nominal Alum Wire dia.

mm

Nominal Sheath thickness

mm

Reference Overall Diameter

mm

Reference Weight

Kg/Km

2x2.5

2

0.8

0.8

1.8

15

425

2x4

2.6

1

0.8

1.8

17

525

2x6

3.1

1

1.25

1.8

19

775

2x10

4

1

1.25

1.8

20

825

2x16

5

1

1.25

1.8

21

950

2x25

6.3

1

1.25

1.8

23

1150

2x35

7.4

1.2

1.6

1.8

27

1700

2x2.5

2

1.2

1.6

1.8

29

2050


Three cores(Galvanized steel wire armored)

Nominal Area

mm²

Reference conductor Diameter

mm

Nominal Insulation thickness

mm

Nominal Alum Wire dia.

mm

Nominal Sheath thickness

mm

Reference Overall Diameter

mm

Reference Weight

Kg/Km

3x2.5 rm

2

0.8

0.8

1.8

16

465

3x4 re

2.3

1

1.25

1.8

18

685

3x4 rm

2.6

1

1.25

1.8

19

725

3x6 re

2.8

1

1.25

1.8

19

800

3x6 rm

3.1

1

1.25

1.8

20

850

3x10 re

3.6

1

1.25

1.8

21

1000

3x10 rm

4

1

1.25

1.8

22

1050

3x16 rm

5

1

1.25

1.8

24

1350

3x25 rm

6.3

1.2

1.6

1.8

29

1975

3x35 rm

7.4

1.2

1.6

1.8

31

2300

3x50 sm

-

1.4

1.6

2

32

2675

3x70 sm

-

1.4

2

2.1

36

3700

3x95 sm

-

1.6

2

2.2

41

4750

3x120 sm

-

1.6

2

2.3

44

5575

3x150 sm

-

1.8

2.5

2.5

49

7150

3x185 sm

-

2

2.5

2.7

53

8550

3x240 sm

-

2.2

2.5

2.9

59

10700

3x300 sm

-

2.4

2.5

3.1

65

12925


Three cores+1(Galvanized steel wire armored)
 

Nominal Area

mm²

Reference conductor Diameter

mm

Nominal Insulation thickness

mm

Nominal Alum Wire dia.

mm

Nominal Sheath thickness

mm

Reference Overall Diameter

mm

Reference Weight

Kg/Km

3x10 rm+6

4.01

3.1

1

1.2

1.25

1.8

3x16 rm+10

5.03

4

1

1.2

1.6

1.8

3x25 rm+16

6.3

5

1

1.2

1.6

1.8

3x35 sm+16

-

5

1

1.2

1.6

1.9

3x50 sm+25

-

6.3

1.2

1.2

2

2

3x70 sm+35

-

7.4

1.2

1.2

2

2.1

3x95 sm+50

-

8.8

1.4

1.2

2

2.3

3x120 sm+70

-

10.6

1.4

1.2

2.5

2.5

3x150 sm+70

-

10.6

1.4

1.4

2.5

2.6

3x185 sm+95

-

12.4

1.6

1.4

2.5

2.7

3x240 sm+120

-

14

1.6

1.5

2.5

2.9

3x300 sm+150

-

15.5

1.8

1.6

2.5

3.1


Four cores(Galvanized steel wire armored)
 

Nominal Area

mm²

Reference conductor Diameter

mm

Nominal Insulation thickness

mm

Nominal Alum Wire dia.

mm

Nominal Sheath thickness

mm

Reference Overall Diameter

mm

Reference Weight

Kg/Km

4x4 re

2.3

1

1.25

1.8

19

790

4x4 rm

2.6

1

1.25

1.8

20

825

4x6 re

2.8

1

1.25

1.8

21

925

4x6 rm

3.1

1

1.25

1.8

21

975

4x10 re

3.6

1

1.25

1.8

23

1175

4x10 rm

4

1

1.25

1.8

24

1250

4x16 rm

5

1

1.6

1.8

27

1750

4x25 rm

6.3

1.2

1.6

1.8

31

2375

4x35 sm

-

1.2

1.6

1.9

31

2600

4x50 sm

-

1.4

2

2.1

37

3625

4x70 sm

-

1.4

2

2.2

40

4575

4x95 sm

-

1.6

2.5

2.4

46

6350

4x120 sm

-

1.6

2.5

2.5

50

7525

4x150 sm

-

1.8

2.5

2.7

55

8950

4x185 sm

-

2

2.5

2.9

60

10650

4x240 sm

-

2.2

2.5

3.1

66

13575

4x300 sm

-

2.4

2.5

3.3

73

16425

 

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article

Category