可信组件

Copyright Liaoning Create Cable Co.,Ltd.  All rights reserved  辽ICP备10201789号   Powered by 300.cn ShenYang

Name

Photovoltaic Solar UL4703 Cable

Affiliate classification
Quantity
-
+
没有此类产品
Detail
Application
These cables are designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.
 
Standard and Approval
2PfG 1169/08.2007 (PV1-F),H1Z2Z2-K,UL4703
 
Cable construction
Conductor: Stranded tinned copper conductor per DIN VDE 0295 and IEC 60228 Class 5.
Insulation: Electron beam cross-linked, halogen free and flame retardant compound.
Sheath: Electron beam cross-linked, halogen free and flame retardant compound, Black
 
Electrical Properties
Rated Voltage U0/U: 0.6/1 kV AC; 0.9/1.5 kV DC
Maximum Permitted DC Voltage: 1.8 kV DC (conductor/conductor, non earthed system, circuit not under load)
Insulation Resistance: 1000 MΩ-km
Spark Test: 6000 Vac (8400 Vdc)
Voltage Withstand: 6500 Vac for 5 min
 
Thermal Properties
Maximum Voltage: Ambient Temperature: -40℃ ~ +90℃
Maximum Temperature At Conductor: 120℃ (20000h) according to IEC/EN 60216-1
Short Circuit Temperature: 200℃/5 sec
Thermal Endurance Test: According to EN 60216-2 (temperature index +120° C)
High Temperature Pressure Test: According to EN 60811-3-1 Damp-Heat Resistance: According to EN 60068-2-78 with 85% humidity
 
Mechanical Properties
Minimum Bending Radius: 4×OD (fixed), 5×OD (flexing)
Dynamic Penetration: According to 2 PfG 1169/08.2007 Annex F
Notch Propagation: According to 2 PfG 1169/08.2007 Annex G
Tensile Strength And Elongation Of Insulation And Jacket: According to EN 60811
Anticipated Period Of Use: 25 years
 
Chemical Properties
Ozone Resistance: According to EN 50396 part 8.1.3 Method B
Weathering- UV Resistance: According to HD 605/A1
Ammoniac resistant
Very good resistance to oils and chemicals
High wear and robust, abrasion resistant
Acid & Alkaline Resistance: According to EN 60811-2-1 (Oxal acid and sodium hydroxide)
 
EC directives
The cables are conform to the EC directives CE 2006/95/EC (Low voltage directive) and RoHS 2002/95/EC
(Restriction of Hazardous Substances)
 
Fire Performance
Flame retardant according to EN 50265-2-1, IEC 60332-1, VDE 0482-332-1-2, DIN EN 60332-1-2
Low smoke emission according to IEC 61034, EN 50268
Halogen free according to EN 50267-2-1, IEC 60754-1
Low corrosivity of gases according to EN 50267-2-2, IEC 60754-2
 


Dimensions and Weight

#×mm² Insulation thickness/mm Sheath thickness/mm  Overall Diameter/mm Copper weight kg/Km
1×1.5 1.58 1.14 0.82 5.4
1×2.5 2.04 1.14 0.82 5.8
1×4.0 2.59 1.14 0.82 6.4
1×6.0 3.17 1.14 0.82 7.0
1×10 4.07 1.52 0.82 8.6
1×16 5.22 1.52 0.82 9.8
1×25 6.51 1.52 0.82 11.1
1×35 7.71 1.52 0.82 12.3
Corresponding parameter set not found, please add it in property template of background