Category
POWER CABLE
- 600/1000V, PVC Insulated Cables according to IEC 60502-1
- 600/1000V, PVC Insulated Cables according to IEC 60502-1 (armored)
- 600/1000V, XLPE Insulated Cables according to IEC 60502-1
- 600/1000V, XLPE Insulated Cables according to IEC 60502-1(armored)
- 8.7/15Kv Single Core Cables according to IEC 60502
- 8.7/15Kv Single Core Cables according to IEC 60502(armored)
- 8.7/15Kv Three Core Cables according to IEC 60502
- 8.7/15Kv Three Core Cables according to IEC 60502(armored)
- NYY-J/-O
- NYCWY
- NYCY
CONTROL CABLE
INSTRUMENTATION CABLE
ELEVATOR CABLE
HARMONIZED CODE CABLE
H03V2V2-F,H03V2V2H2-F,H05V2V2-F,H05V2V2H2-F
Key words:
Classification:
Product Description
Application
This cable cables are suitable for domestic premises, kitchen, office for light service
or light portable apparatuses. With their special insulation and sheath compounds
Implementation of standards
IEC 60332-1
Comply with EN50265-2-1,CE's.
Technical parameters
| Rated voltage | H03V2V2-F:300/300V; |
| H03V2V2H2-F:300/300V | |
| H05V2V2-F:300/500V | |
| H05V2V2H2-F:300/500V | |
| Temperature range | Flexing:-5℃~+90℃ |
| Fixed installation:-40℃~+90℃ | |
| Test voltage | AC:50HZ 3000V |
| Min bending radius | 4×Cable diameter |
| Production of material does not contain cadmium and silicone, free of paint. Moisture resistant properties of harmful substances, conforms to the RoHS standard. | |
| PVC self-extinguishing and flame retardant,Test method according to:IEC 60332 | |
Specification range
| Type | No. core | Cross section (mm2) | Conductor structure (number / diameter) | Insulation Thickness (mm) | Insulation diameter (mm) | Copper weight (kg/km) | Approx weight (kg/km) |
| H03V2V2-F | 2 | 0.5 | 28×0.15 | 0.5 | 1.9 | 9.6 | 38 |
| 2 | 0.75 | 42×0.15 | 0.5 | 2.2 | 14.4 | 46 | |
| 3 | 0.5 | 28×0.15 | 0.5 | 4.3 | 14.4 | 45 | |
| 3 | 0.75 | 42×0.15 | 0.5 | 2.2 | 21.6 | 59 | |
| H03V2V2H2-F | 2 | 0.5 | 28×0.15 | 0.5 | 1.9 | 9.7 | 32 |
| 2 | 0.75 | 42×0.15 | 0.5 | 2.2 | 14.4 | 35 |
| Type | No. core | Cross section (mm2) | Conductor structure (number / diameter) | Insulation Thickness (mm) | Insulation diameter (mm) | Copper weight (kg/km) | Approx weight (kg/km) |
| H05V2V2-F | 2 | 0.75 | 42×0.15 | 0.6 | 2.3 | 14.4 | 54.2 |
| 1.00 | 32×0.20 | 0.6 | 2.4 | 19 | 60.5 | ||
| 1.50 | 48×0.20 | 0.7 | 3.0 | 29 | 82.3 | ||
| 2.50 | 49×0.25 | 0.8 | 3.6 | 48 | 129.1 | ||
| 3 | 0.75 | 42×0.15 | 0.6 | 2.3 | 21.6 | 65 | |
| 1.00 | 32×0.20 | 0.6 | 2.4 | 29 | 73.1 | ||
| 1.50 | 48×0.20 | 0.7 | 3.0 | 43 | 104.4 | ||
| 2.50 | 49×0.25 | 0.8 | 3.6 | 72 | 163 | ||
| 4 | 0.75 | 42×0.15 | 0.6 | 2.3 | 29 | 77.7 | |
| 1.00 | 32×0.20 | 0.6 | 2.4 | 38 | 93 | ||
| 1.50 | 48×0.20 | 0.7 | 3.0 | 58 | 131.7 | ||
| 2.50 | 49×0.25 | 0.8 | 3.6 | 96 | 199.6 | ||
| 5 | 0.75 | 42×0.15 | 0.6 | 2.3 | 36 | 97.3 | |
| 1.00 | 32×0.20 | 0.6 | 2.4 | 48 | 111.7 | ||
| 1.50 | 48×0.20 | 0.7 | 3.0 | 72 | 163.1 | ||
| 2.50 | 49×0.25 | 0.8 | 3.6 | 120 | 245.4 | ||
| H05V2V2H2-F | 2 | 0.75 | 42×0.15 | 0.6 | 2.3 | 14.1 | 48 |
| 1.00 | 32×0.20 | 0.6 | 2.4 | 19 | 57 |
Related Products