Product Description
Application and Description
These cables are flexible rubber insulated; rubber jacketed harmonized cord, recommended for use in equipment, which is subject to light and medium stresses in both dry and damp environments. For use with electronics and electrical equipment such as appliances, small hand tools and office equipment They can be found in flat irons, soldering irons, kitchen aids, toasters, stoves and in connections with light commercial electric tools. Also suitable for fixed installation in furniture, decorative coverings, wall partitions and prefabricated building parts. Max operating voltage in single or three phase system is Uo/U 300/500 volts. In a direct current system max operating voltage is Uo/U 413/825 volts. Outdoor use is permitted only for a short time. They are ozone resistant, oil & fat resistant.
Standard and Approval
<HAR> HD22.4 S3, VDE-0282 Part-4, CEI 20-19/4 / 20-35 (EN60332-1), CE low voltage directive 73/23/EEC & 93/68/EEC., IEC 60245-4, ROHS compliant
Cable Construction
Fine bare copper strands
Strands to VDE-0295 Class-5, IEC 60228 Class-5
Rubber core insulation EI4 to VDE-0282 Part-1
Color code VDE-0293-308 and HD 186
Green-yellow grounding, 3 conductors and above
Polychloroprene rubber (neoprene) jacket EM3
Technical Characteristics
| WORKING VOLTAGE | 300/500V |
| TEST VOLTAGE | 2000V |
| FLEXING BENDING RADIUS | 8ר |
| TEMPERATURE RANGE | -30 ºC to +60 ºC |
| SHORT CIRCUIT TEMPERATURE | +200 ºC |
| FLAME RETARDANT | IEC 60332 -1 |
| INSULATION RESISTANCE | 20MΩ x km |
| HALOGEN-FREE | IEC 60754-1 |
| LOW SMOKE | IEC 60754-2 |
Cable Parameter
| #×MM² | Insulation thickness | Sheath thickness | Overall Diameter | Copper weight |
| 2 x 0.75 | 0.6 | 0.8 | 5.7-7.4 | 14.4 |
| 3 x 0.75 | 0.6 | 0.9 | 6.2-8.1 | 21.6 |
| 4 x 0.75 | 0.6 | 0.9 | 6.8-8.8 | 28.8 |
| 5 x 0.75 | 0.6 | 1.0 | 7.6-9.9 | 36.0 |
| 2 x 1 | 0.6 | 0.9 | 6.1-8.0 | 19.0 |
| 3 x 1 | 0.6 | 0.9 | 6.5-8.5 | 29.0 |
| 4 x 1 | 0.6 | 0.9 | 7.1-9.3 | 38.4 |
| 5 x 1 | 0.6 | 1.0 | 8.0-10.3 | 48.0 |
| 2 x 1.5 | 0.8 | 1.0 | 7.6-9.8 | 29.0 |
| 3 x 1.5 | 0.8 | 1.0 | 8.0-10.4 | 43.0 |
| 4 x 1.5 | 0.8 | 1.1 | 9.0-11.6 | 58.0 |
| 5 x 1.5 | 0.8 | 1.1 | 9.8-12.7 | 72.0 |
| 2 x 2.5 | 0.9 | 1.1 | 9.0-11.6 | 48.0 |
| 3 x 2.5 | 0.9 | 1.1 | 9.6-12.4 | 72.0 |
| 4 x 2.5 | 0.9 | 1.2 | 10.7-13.8 | 96.0 |
| 5 x 2.5 | 0.9 | 1.3 | 11.9-15.3 | 120.0 |